| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Vue Vben Admin 2.10.1 allows unauthorized login to the backend due to an issue with hardcoded credentials. |
| The standard user uses the run as function to start the MEAC applications with administrative privileges. To ensure that the system can startup on its own, the credentials of the administrator were stored. Consequently, the EPC2 user can execute any command with administrative privileges. This allows a privilege escalation to the administrative level. |
| Seth Fogie, member of the AXIS Camera Station Pro Bug Bounty Program, has found that the Incident report feature may expose sensitive credentials on the AXIS Camera Station windows client. If Incident report is not being used with credentials configured this flaw does not apply.
Axis has released patched versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext credentials of AD and system mail from the system frontend. |
| An issue in the luci-mod-rpc package in OpenWRT Luci LTS allows for privilege escalation from an admin account to root via the JSON-RPC-API, which is exposed by the luci-mod-rpc package |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files. |
| Onyxia is a data science environment for kubernetes. In versions 4.6.0 through 4.8.0, Onyxia-API leaked the credentials of private helm repositories in the public (unauthenticated) /public/catalogs endpoint.vOnly instances using private helm repositories (i.e setting username & password in the catalogs configuration) are affected. This is fixed in version 4.9.0. |
| The exposure of credentials in the call forwarding configuration module in MeetMe products in versions prior to 2024-09 allows an attacker to gain access to some important assets via configuration files. |
| STMicroelectronics SPC58 is vulnerable to Missing Protection Mechanism for Alternate Hardware Interface. Code running as Supervisor on the SPC58 PowerPC microcontrollers may disable the System Memory Protection Unit and gain unabridged read/write access to protected assets. |
| The Janssen Project is an open-source identity and access management (IAM) platform. In versions 1.9.0 and below, Janssen stores passwords in plaintext in the local cli_cmd.log file. This is fixed in the nightly prerelease. |
| Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior. |
| Cryptographic key extraction from internal flash in Minut M2 with firmware version #15142 allows physically proximate attackers to inject modified firmware into any other Minut M2 product via USB. |
| MTPutty 1.0.1.21 contains a sensitive information disclosure vulnerability that allows local attackers to view SSH connection passwords through Windows PowerShell process listing. Attackers can run a PowerShell command to retrieve the full command line of MTPutty processes, exposing plaintext SSH credentials. |
| MinIO Operator STS is a native IAM Authentication for Kubernetes. Prior to version 7.1.0, if no audiences are provided for the `spec.audiences` field, the default will be of the Kubernetes apiserver. Without scoping, it can be replayed to other internal systems, which may unintentionally trust it. This issue has been patched in version 7.1.0. |
| The Avalara for Salesforce CPQ app before 7.0 for Salesforce allows attackers to read an API key. NOTE: the current version is 11 as of mid-2024. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue. |
| H3C ER8300G2-X is vulnerable to Incorrect Access Control. The password for the router's management system can be accessed via the management system page login interface. |
| A password is exposed locally. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |