| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if session administrator credentials become compromised.
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may
be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst)
This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2. |
| Remote Code Execution vulnerabilities are present in ASPECT if session administrator credentials become compromised
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Device commissioning parameters in ASPECT may be modified by an external source if administrative credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Improper Input Validation vulnerability in ABB 800xA Base.
An attacker who successfully exploited this
vulnerability could cause services to crash by sending specifically crafted messages.
This issue affects 800xA Base: from 6.0.0 through 6.1.1-2. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| An attacker could exploit the vulnerability by
injecting garbage data or specially crafted data. Depending on the data injected each process might be
affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing
the product to store wrong information or act on wrong data or display wrong information.
This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
For an attack to be successful, the attacker must have local access to a node in the system and be able to
start a specially crafted application that disrupts the communication.
An attacker who successfully exploited the vulnerability would be able to manipulate the data in such
way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300
and AdvaBuild to crash. |
| AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the
command queue can use it to launch an attack by running any executable on the AdvaBuild node. The
executables that can be run are not limited to AdvaBuild specific executables.
Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. |
| An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible.
The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system.
Below are reported vulnerabilities in the Robot Ware versions.
* IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07
* OmniCore- RobotWare 7 < 7.14 |
|
An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible, or execute arbitrary code.
The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system.
Below are reported vulnerabilities in the Robot Ware versions.
* IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07
* OmniCore- RobotWare 7 < 7.14
|
| FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |